Massachusetts Maritime Academy
Client: Massachusetts Maritime Academy
Project Location: Buzzards Bay, Massachusetts
Project Size: 10,000 SF
Project Type: Roof Replacement
Scope:
Massachusetts Maritime Academy required a roof system replacement at the Facilities Department Building due to several ongoing active leaks both under the original roof which was installed in 1999 and a section of rubber roof which was replaced in 2020.
Services:
Removal of existing roof system down to the structural deck.
Remove and dispose of the existing 80 square PVC roof assembly and all components, down to the wooden deck.
Install new drains to meet state plumbing codes.
Mechanically attach flat & tapered polyisocyanurate insulation, per wind-uplift test adhesion patterns and to meet building code.
Adhere ½” gypsum coverboard in foam insulation adhesive.
Adhere 2 modified base plies to gypsum coverboard in cold adhesive at rate of 2.5 gallons per sq.
Adhere mineral surface modified cap sheet to base ply in cold adhesive at rate of 2.5 gallons per sq.
Attach ANSI-SPRI certified metal edge system.