Framingham State University
Warren Conference Center and Inn
Client: The Whiting-Turner Contracting Company
Project Location: Framingham, Massachusetts
Project Type: Addition
Scope:
Building envelope commissioning as part of a renovation and addition included, but was not limited to:
Horizontal and Vertical Waterproofing
Joint Sealants
Insulation
Air, Vapor, Water Barriers
EPDM Roofing
Services:
Peer Review and red-line drawing comments of the design and prepared a follow-up report
Construction site visits to observe progress of the building envelope system installation
Window testing
ASTM E783 – Standard Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors.
ASTM E1105 – Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors and Curtain Wall by Uniform or Cyclic Static Air Pressure.
AAMA 501.3 - Field Check of Water and Air leakage through Installed Exterior Windows, Curtain Walls, and Doors by Uniform Air Pressure Difference
AMMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems.